Microprocessor Flame photometer
Microprocessor Flame photometer
Microprocessor Flame photometer
Salient Features:
Microprocessor Based with Printer Interface
Auto Gas Cutoff facility
Auto Flame Failure Detection
Five Measurements in Single Aspiration of the sample
Calibration Curve Programmability Using Maximum of 5 Standard
Data Processing Through Curve Fitting Techniques- Least Squares, Quadratic
Multiple Calibration Curves Saving Facility
Printer Attachment Facility
Measurement can be done in ppm as well as in meq
Setup Storage Facility (up to 10 setup files)
Sample Data Storage Facility
Direct Results in ppm and meq.
Useful for both Medical & Soil Testing Applications
Microprocessor Flame Photometers 1600-G comes with Flame Failure detection and Auto Gas Cutoff Facility. In case of power failure, the gas cuts off automatically. In case the flame goes off accidently during work, the flame failure alarm sounds after a few seconds.
Microprocessor Flame Photometer 1600-G are used for the determination of Sodium, Potassium, Calcium, Lithium & Barium. They use the latest microcontroller technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility. They have soft touch membrane keys for ease of operation. The solution is aspirated through an atomizer. Air, sample and the fuel are mixed in the mixing chamber which is then sprayed as a very fine mist into the flame. Radiations from the flame passes through specific narrow band interference filter and pass to the photo-detector. The final results are displayed on the 128 x 64 alphanumeric LCD. The standard model comes with 2 filters (Na, K). Additional filters Ca & Li are optional at extra cost.
A photoelectric flame photometer is a device used in inorganic chemical analysis to determine the concentration of certain metal ions.
MODEL
2600-G : sodium, Na,Potassium K
1600-G : Sodium, potassium, calcium, lithium
RANGE
General
Serum
Urine
ppm
meq/l
meq/l
meq/l
Na: 0 – 100
Upto 250 meq/l,
Na: 0 – 200
Na: 0 – 250
ppm
1:100 dil.
1:100 dil
1:100 dil
K: 0 – 100 ppm
Upto 250 meq/l,
K:0–100
K:0–100
1:100 dil
1:100 dil
1:100 dil
RANGE
Ca: 0 – 100
Upto 250 meq/l,
–
Ca: 0 – 10
1:100 dil
Li: 0 – 2
1:2 dil
ppm
Upto 250 meq/l,
1:5 dil
–
1:100 dil
Li: 0 – 100 ppm
–
Ba: 0 – 100
ppm
Sensitivity
General: Na: 0.5 ppm, K: 0.5 ppm, Ca: 15 ppm, Li: 0.5 ppm, Ba: 30 ppm
Filters
Na & K supplied (Ca, Li and Ba are optional at extra cost) {Ba can be factory
fitted only}
Resolution
0.1 ppm/0.1 meq
Reproducibility
< 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as
maximum standard
Linearity
< 2% error when 3 ppm Na/K and 5 ppm Li are set as maximum standard
Curve Fit
< 2% of FS
Accuracy
Display
128x64 Alphanumeric LCD with backlit
Average Time
In-built in software
Flame System
LPG and Dry Oil Free Sir
Detector
Silicon Photodiode
Calibration
Up to 5 Point Calibration with Curve Fitting Software
Gas Control
Adjustable with knobs
Flame Failure
Auto Detection
Gas Cutoff
Automatic
Ignition System
Auto Ignition
Automiser
Axial flow type
Printer
Provision for attachment of dot matrix printer or HP LaserJet/ inkjet (non-
windows) printers with USB interface
Power
230 V ± 10% AC, 50 Hz
Dimensions
285 x 255 x 210 mm (L x B x H) (Approx.)
Weight
7.5 Kg (Approx.)
COMPRESSOR UNIT
Air Supply
By oil free mini compressor unit with pressure regulator
Combustion Gas
LPG controlled by precision regulator
Power
230 V ± 10% AC, 50 Hz
Dimensions
290 x 255 x 210 mm (L x B x H) (Approx.)
Weight
8 Kg (Approx.)
ACCESSORIES
Power Cord
1 Unit
AIR PIPE
1 Unit (Air Tubing with end clamps)
GAS PIPE
1 Unit
WASTE WATER PIPE
1 Unit
BEAKER BOX
1 Unit (Contains 5 Beakers)
CHIMNEY
1 Unit
INSTRUCTION
1 Unit
MANUAL
CAPILLARY PIPES
3 Unit
Note: Specifications are subject to change due to continuous improvements.